Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Acta cir. bras ; 27(7): 494-498, jul. 2012. tab
Article in English | LILACS | ID: lil-640099

ABSTRACT

PURPOSE: The objective of this study was to assess the cytokine serum levels of IL-6 and TNF-α in rats subjected to fecal peritonitis and treated with peritoneal lavage with 0.2% ropivacaine by peritoneal lavage. METHODS: We subjected 16 Wistar rats to laparotomy 6 hours after the induction of fecal peritonitis with autogenous stool and subsequently divided the rats randomly into 4 groups: I-control, no treatment; II- drying of the abdominal cavity; III- lavage of the abdominal cavity with 3 mL of 0.9% normal saline and drying; IV- lavage of the abdominal cavity with 3 mL of 0.2% ropivacaine and drying. Six hours following the laparotomy, the animals underwent cardiac puncture, and 1 mL of blood was collected for cytokine assessment before the animals were euthanized. RESULTS: The lavage with ropivacaine resulted in smaller TNF-α levels compared with those observed in the other treatment groups (p <0.05). Regarding IL-6, the ropivacaine group showed lower cytokine levels than those observed in groups I and II, but there was no significant difference (p> 0.05) between groups III and IV. CONCLUSION: Peritoneal lavage with 0.2% ropivacaine was shown to reduce plasma levels of IL-6 and TNF-α in the treatment of fecal peritonitis in rats.


OBJETIVO: O objetivo do presente estudo foi avaliar as dosagens séricas das citocinas Il-6 e TNF-α em ratos submetidos à peritonite fecal e tratados com lavagem peritoneal com ropivacaína a 0,2%. MÉTODOS: Utilizaram-se 16 ratos Wistar, submetidos à laparotomia 6 horas após a indução de peritonite fecal com fezes autógenas, distribuídos aleatoriamente em 4 grupos: I- Controle, nenhum tratamento; II- Enxugamento da cavidade abdominal; III- Lavagem da cavidade abdominal com 3 ml de solução salina 0,9% e enxugamento; IV- Lavagem da cavidade abdominal com 3 ml de ropivacaína a 0,2% e enxugamento. Seis horas após a laparotomia os animais foram submetidos à punção cardíaca com retirada de 1 mL de sangue para a dosagem das citocinas e, a seguir, eutanasiados. RESULTADOS: A lavagem com ropivacaína apresentou valores de TNF-α menores do que os observados com os outros tratamentos (p<0,05). Em relação aos valores da IL-6, o grupo da ropivacaína apresentou valores menores do que os observados com os grupos I e II, mas não houve diferença estatística (p>0,05) em relação ao grupo III. CONCLUSÃO: A lavagem peritoneal com ropivacaína a 0,2% no tratamento da peritonite fecal em ratos demonstrou reduzir os níveis plasmáticos de IL-6 e do TNF-α.


Subject(s)
Animals , Male , Rats , Amides/therapeutic use , Anesthetics, Local/therapeutic use , /blood , Peritoneal Lavage/methods , Peritonitis/blood , Peritonitis/drug therapy , Tumor Necrosis Factor-alpha/blood , Feces , Injections, Intraperitoneal , Peritoneal Lavage/adverse effects , Random Allocation , Rats, Wistar , Treatment Outcome
2.
Rev. bras. anestesiol ; 62(3): 435-438, maio-jun. 2012.
Article in Portuguese | LILACS | ID: lil-626519

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A existência de um ambiente rico em oxigênio, material combustível em abundância e a utilização de aparelhos capazes de fornecerem ignição transformam a sala cirúrgica em um ambiente de risco para a ocorrência de incêndios. Apesar de rara, trata-se de uma complicação potencialmente grave e na maioria das vezes evitável. Relatamos um caso de incêndio no campo cirúrgico durante uma cirurgia de blefaroplastia em que foi suplementado oxigênio por meio de cateter nasal. RELATO DO CASO: Paciente de 52 anos, sexo feminino, sem comorbidades, admitida para realização de blefaroplastia bilateral. Após monitorização e venóclise, procedeu-se à sedação endovenosa com oferta de oxigênio suplementar por meio de cateter tipo óculos, com fluxo de 4 L.min-1, seguida de anestesia local das pálpebras. Durante o ato cirúrgico, a utilização do bisturi elétrico ocasionou combustão dos campos cirúrgicos e queimaduras na face da paciente. CONCLUSÕES: O anestesiologista desempenha papel fundamental na prevenção de incêndio na sala cirúrgica, reconhecendo possíveis fontes de ignição e administrando de forma racional o oxigênio, principalmente com sistemas abertos. O primeiro passo para a prevenção deve ser a lembrança constante da possibilidade de incêndio.


BACKGROUND AND OBJECTIVES: There are several factors in operating rooms that increase the risk of fire. Besides being an oxygen-enriched environment, it contains combustible materials and equipment with available ignition sources. Although fires in operating rooms are a relatively rare event, the consequences are potentially serious and mostly avoidable. We present a case report of a fire occurring in the surgical drape during a blepharoplasty in which oxygen was supplemented by nasal catheter. CASE REPORT: Female patient, 52-years old, without comorbidities, admitted to hospital for a bilateral blepharoplasty. After monitoring and venoclysis, the patient underwent intravenous sedation and additional oxygen given via spectacle-type catheter at a flow rate of 4 L.min-1, followed by local anesthesia in the eyelids. During surgery, the use of electric scalpel provoked combustion in the surgical drapes and burns on the patient's face. CONCLUSIONS: Anesthesiologists play an important role preventing fire in operating rooms, as they can recognize possible ignition sources and rationally administer the oxygen, especially in open systems. The first step toward prevention is to be constantly aware of potential fire.


JUSTIFICATIVA Y OBJETIVOS: La existencia de un ambiente rico en oxígeno, material combustible en abundancia, y la utilización de aparatos capaces de realizar la ignición, transforma el quirófano en un ambiente de riesgo para el conato de incendios. A pesar de ser una complicación rara, es potencialmente grave y en la mayoría de los casos se puede evitar. Relatamos aquí un caso de incendio en el ambiente quirúrgico durante una cirugía de blefaroplastia en que fue suministrado oxígeno por medio de un catéter nasal. RELATO DEL CASO: Paciente de 52 años, del sexo femenino, sin comorbilidades, admitido para la realización de blefaroplastia bilateral. Posteriormente a la monitorización y a la venoclisis, se procedió a la sedación endovenosa con oferta de oxígeno suplementario por medio de un catéter tipo gafas con flujo de 4 L.min-1, seguida de anestesia local en los párpados. Durante la operación, la utilización del bisturí eléctrico creó una combustión de los campos quirúrgicos produciendo quemaduras en la cara de la paciente. CONCLUSIONES: El anestesiólogo desempeña un rol fundamental en la prevención del incendio en el quirófano, reconociendo posibles fuentes de ignición y administrando de forma racional el oxígeno, principalmente con sistemas abiertos. El primer paso para su prevención es estar siempre alertas sobre la posibilidad de que se pueda producir un incendio.


Subject(s)
Humans , Female , Middle Aged , Surgery Department, Hospital/organization & administration , Fire Extinguishing Systems/standards , Fires/prevention & control , Blepharoplasty/instrumentation , Anesthesia, Local/instrumentation
3.
Acta cir. bras ; 27(2): 193-199, Feb. 2012. ilus, graf
Article in English | LILACS | ID: lil-614541

ABSTRACT

PURPOSE: To evaluate the histological features in lungs, peritoneum and liver of rats subjected to fecal peritonitis and treated with peritoneal lavage with 0.2 percent ropivacaine. METHODS: Twenty Wistar rats were subjected to laparotomy 6 h after the fecal peritonitis induction with autogenous stool. Rats were randomly distributed into 4 groups: I - (n=5) Control, no treatment; II - (n=5) Drying of the abdominal cavity; III - (n=5) Abdominal cavity lavage with 3 ml 0.9 percent saline solution and drying; and IV - (n=5) Abdominal cavity lavage with 3 ml 0.2 percent ropivacaine and drying. The animals that died underwent necropsy, and the surviving ones were subjected to euthanasia on the 11th day post-surgery. Fragments of liver, lungs and peritoneum were removed for histological evaluation. RESULTS: The animals that received peritoneal lavage (groups III and IV) showed greater survival than the drying and control groups. Lavage with ropivacaine prevented death during the observed period. Peritoneal lavage with ropivacaine maintained the architecture of the lung, peritoneum and liver without any important histological alterations. The histopathological findings analyzed correlated with greater survival of group IV. CONCLUSION: Treatment of fecal peritonitis in rats with peritoneal lavage using 0.2 percent ropivacaine demonstrated a reduction in histopathological alterations related to inflammatory response and sepsis.


OBJETIVO: Avaliar os aspectos histopatológicos em pulmões, peritônios e fígados de ratos submetidos à peritonite fecal e tratados com lavagem peritoneal com ropivacaína a 0,2 por cento. MÉTODOS: Utilizou-se 20 ratos Wistar, submetidos à laparotomia 6 horas após a indução de peritonite fecal com fezes autógenas, distribuídos aleatoriamente em quatro grupos: I- (n=5) Controle, nenhum tratamento; II- (n=5) Enxugamento da cavidade abdominal; III- (n=5) Lavagem da cavidade abdominal com 3 ml de solução salina 0,9 por cento e enxugamento ; IV- (n=5) Lavagem da cavidade abdominal com 3 ml de ropivacaína a 0,2 por cento e enxugamento. Os animais que morreram foram necropsiados e os sobreviventes foram eutanasiados no 11º dia do pós-operatório. Retirou-se fragmentos do fígado, pulmões e do peritônio dos animais para estudo histopatológico. RESULTADOS: Os animais que receberam lavagem peritoneal (grupos III e IV) apresentaram maior sobrevida que os grupos enxugamento e controle. A lavagem com ropivacaína impediu o óbito no período avaliado. A lavagem peritoneal com ropivacaína manteve a arquitetura do pulmão, peritônio e fígado sem alterações histológicas importantes. Os achados histopatológicos analisados foram condizentes com o maior tempo de sobrevida no grupo IV. CONCLUSÃO: A lavagem peritoneal com ropivacaína a 0,2 por cento no tratamento da peritonite fecal em ratos demonstrou reduzir as alterações histopatológicas relacionados à resposta inflamatória e sepse.


Subject(s)
Animals , Male , Rats , Amides/therapeutic use , Anesthetics, Local/therapeutic use , Peritoneal Lavage/methods , Peritonitis/drug therapy , Feces , Liver/drug effects , Liver/pathology , Lung/drug effects , Lung/pathology , Peritoneum/drug effects , Peritoneum/pathology , Peritonitis/pathology , Random Allocation , Rats, Wistar , Sepsis/drug therapy , Time Factors , Treatment Outcome
4.
Rev. bras. anestesiol ; 61(6): 781-785, nov.-dez. 2011. ilus, graf
Article in Portuguese | LILACS | ID: lil-605958

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A introdução da circulação extracorpórea (CEC) na prática clínica foi decisiva para o desenvolvimento da cirurgia cardiovascular moderna. A adição de novos procedimentos e equipamentos, entretanto, traz riscos e complicações inerentes. O objetivo deste relato é descrever um caso de mau funcionamento do sistema de oxigenação e enfatizar a importância da interação entre a equipe médica para prevenir erros e reduzir complicações. RELATO DO CASO: Durante a realização de cirurgia para troca valvar e correção de CIV, observou-se coloração escura do sangue na saída do oxigenador. Exames laboratoriais demonstraram acidose e hipoxemia grave. Todo o sistema foi reavaliado, mas a causa do mau funcionamento não foi encontrada. Medidas para a redução do dano foram instituídas com sucesso. Após a cirurgia, todo o sistema de CEC foi submetido à avaliação técnica. CONCLUSÕES: A interação entre a equipe, o diagnóstico precoce e a intervenção imediata mostraram-se fundamentais para o desfecho favorável.


BACKGROUND AND OBJECTIVES: The introduction of extracorporeal circulation in clinical practice was decisive for the development of modern cardiovascular surgery. Addition of new procedures and equipment, however, brings inherent risks and complications. The objective of this report is to describe a malfunction of the oxygenation system and emphasize the importance of the interaction among the medical team members to prevent errors and complications. CASE REPORT: During valve replacement and IVC correction surgery, we observed a darker shade of red in the blood on the exit of the oxygenator. Laboratory tests demonstrated severe acidosis and hypoxemia. The entire system was evaluated, but the cause of the malfunction was not found. Measures to reduce damage were successfully instituted. After the surgery, the whole system underwent technical evaluation. CONCLUSIONS: Interaction among the medical team members, early diagnosis, and immediate intervention were fundamental for a favorable outcome.


JUSTIFICATIVA Y OBJETIVOS: La introducción de la circulación extracorpórea (CEC), en la práctica clínica fue decisiva para el desarrollo de la cirugía cardiovascular moderna. El haber añadido nuevos procedimientos y equipos, sin embargo, conllevó a algunos riesgos y complicaciones inherentes. El objetivo de este relato es describir un caso de mal funcionamiento del sistema de oxigenación, y enfatizar la importancia de la interacción con el equipo médico para prevenir los errores y reducir las complicaciones. RELATO DEL CASO: Durante la realización de la cirugía para el cambio valvular y la corrección de CIV, observamos una coloración oscura de la sangre en la salida del oxigenador. Los exámenes de laboratorio arrojaron acidosis e hipoxemia grave. Todo el sistema se evaluó de nuevo, pero la causa del mal funcionamiento no se encontró. Las medidas para la reducción del daño fueron instauradas con éxito. Después de la cirugía, todo el sistema de CEC fue sometido a la evaluación técnica. CONCLUSIONES: La interacción entre el equipo, el rápido diagnóstico y la intervención inmediata fueron fundamentales para un resultado favorable.


Subject(s)
Humans , Male , Middle Aged , Equipment Failure , Extracorporeal Membrane Oxygenation , Intraoperative Complications
5.
Rev. bras. anestesiol ; 61(5): 607-609, set.-out. 2011.
Article in Portuguese | LILACS | ID: lil-600953

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A gonadotrofina coriônica humana (HCG) e o hormônio tireotrófico (TSH) apresentam analogia entre suas estruturas, assim como seus receptores. Os altos níveis de HCG encontrados nas doenças trofoblásticas gestacionais podem induzir um quadro de hipertireoidismo secundário. O objetivo deste relato é apresentar um caso em que a administração de contraste iodado precipitou um quadro de crise tireotóxica. RELATO DO CASO: Paciente com mola hidatiforme completa foi admitida no centro cirúrgico com sangramento vaginal intenso após realização de tomografia com contraste iodado. Durante indução anestésica, paciente apresentou quadro compatível com crise tireotóxica. CONCLUSÕES: A incidência de quadros graves associados à doença trofoblástica gestacional tende a diminuir com seu diagnóstico precoce. Ainda que isso aconteça, o anestesiologista deve estar atento à possibilidade de crise tireotóxica nesses pacientes.


BACKGROUND AND OBJECTIVES: Human chorionic gonadotropin (HCG) and thyrotrophic hormone (TSH) have analogies in their structures, as well as in their receptors. The high levels of HCG seen in gestational trophoblastic diseases may induce secondary hyperthyroidism. The objective of this report was to present a case in which the administration of iodinated contrast triggered a thyrotoxic crisis. CASE REPORT: Patient with complete hydatidiform mole who was admitted to the operating room with severe vaginal bleeding after a tomographic exam with iodinated contrast. During anesthetic induction, the patient presented symptoms compatible with thyrotoxic crisis. CONCLUSIONS: The incidence of severe presentations associated with gestational trophoblastic disease tends to decrease with early diagnosis. Still, the anesthesiologist should be aware of the possibility of those patients developing thyrotoxic crisis.


JUSTIFICATIVA Y OBJETIVOS: La HCG y el TSH presentan una analogía entre sus estructuras, como también sus receptores. Los altos niveles de HCG encontrados en las enfermedades trofoblásticas de la gestación pueden inducir a un cuadro de hipertiroidismo secundario. El objetivo de este relato es presentar un caso en que la administración de contraste yodado precipitó un cuadro de crisis tirotóxica. RELATO DEL CASO: Paciente con mola hidatiforme completa que entró en quirófano con sangramiento vaginal intenso después de la realización de una tomografía con contraste yodado. Durante la inducción anestésica, la paciente presentó un cuadro compatible con la crisis tirotóxica. CONCLUSIONES: La incidencia de cuadros graves asociados a la enfermedad trofoblástica gestacional tiende a reducirse con su diagnóstico precoz. Pero incluso si eso ocurre, el anestesiólogo debe estar atento a la posibilidad de una crisis tirotóxica en esos pacientes.


Subject(s)
Humans , Female , Adolescent , Hyperthyroidism/complications , Intraoperative Care , Iodopyridones , Hydatidiform Mole/complications , Thyroid Crisis
6.
Rev. bras. anestesiol ; 61(4): 517-521, jul.-ago. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-593251

ABSTRACT

JUSTIFICATIVAS E OBJETIVOS: Ampolas de vidro têm sido amplamente utilizadas no acondicionamento de fármacos. O vidro apresenta importantes características que lhe conferem o uso amplo na fabricação de recipientes para o acondicionamento de fármacos e outras substâncias estéreis. No entanto, a contaminação das soluções com micropartículas de vidro durante a abertura, a presença de metais, acidentes pérfuro-cortantes e contaminações biológicas justificam a necessidade de materiais educativos que orientem a manipulação dessas ampolas. CONTEÚDO: As micropartículas de vidro geradas na abertura das ampolas podem ser aspiradas e injetadas nas mais diversas vias, assim como os metais que contaminaram o conteúdo das ampolas. As contaminações exógenas por vidros e metais podem alcançar diversos sítios no organismo. Desencadeiam-se reações orgânicas que podem dar origem a lesões. Abrir ampolas pode expor o profissional ao risco de lesões pérfuro-cortantes. Essas lesões aumentam o risco biológico em razão de serem a porta de entrada para vírus e bactérias. Sistemas de abertura de ampolas (VIBRAC E OPC) foram desenvolvidos para reduzir a incidência de tais acidentes. Materiais alternativos ao vidro podem representar uma estratégia interessante para aumentar a segurança. O uso de seringas esterilizadas pré-preparadas pelo fabricante pode consistir em uma evolução em relação à segurança. CONCLUSÃO: O treinamento da equipe e o esclarecimento por parte da indústria farmacêutica quanto ao uso de ampolas mostram-se fundamentais na profilaxia de acidentes e contaminações. Ainda é necessário descobrir novos sistemas de abertura de ampolas de forma mais segura. Não menos importante será a busca de materiais seguros que sirvam de alternativa ao uso do vidro.


BACKGROUND AND OBJECTIVE: Glass ampoules have been widely used in packaging injection drugs. Glass has important characteristics that allow it to be widely used in fabrication of recipients for drugs and other sterile substances. However, contamination of solutions with glass microparticles on breaking open glass ampoules, the presence of metals, percutaneous injury, and biological contamination justify the need of educational materials to orient the manipulation of ampoules. CONTENTS: Glass microparticles generated in the snap-opening of ampoules, as well as metals that contaminate their contents can be aspirated and injected through several routes. Exogenous contaminations by glass and metals can reach several sites in the organism. They trigger organic reactions that may give rise to injuries. Opening ampoules can expose professionals to the risk of percutaneous injuries. These lesions increase the biological risk as they are the gateway for viruses and bacteria. Ampoules opening systems (VIBRAC and OPC) have been developed to reduce the incidence of such accidents. Alternative materials to glass may represent an interesting strategy to increase safety. The use of prefilled syringes may represent an evolution regarding safety. CONCLUSIONS: Team training and information provided by the pharmaceutical industry on the use of ampoules are fundamental in the prophylaxis of accidents and contaminations. The search for safer materials to replace glass is also important.


JUSTIFICATIVAS Y OBJETIVOS: Las ampollas de vidrio han sido extensamente utilizadas en el acondicionamiento de fármacos. El vidrio presenta importantes características que le dan la posibilidad de usarse ampliamente en la fabricación de recipientes en el acondicionamiento de fármacos y otras sustancias estériles. Sin embargo, la contaminación de las soluciones con micropartículas de vidrio durante la abertura, la presencia de metales, los accidentes perforo-cortantes y las contaminaciones biológicas, justifican la necesidad del uso de materiales educativos que orienten sobre la manipulación de esas ampollas. CONTENIDO: Las micropartículas de vidrio generadas en la abertura de las ampollas pueden ser aspiradas e inyectadas en las más diversas vías, como también los metales que contaminaron el contenido de esas ampollas. Las contaminaciones exógenas por vidrios y metales pueden alcanzar diversos sitios en el organismo. Se desencadenan entonces reacciones orgánicas que pueden originar lesiones. Abrir ampollas puede exponer al profesional al riesgo de lesiones perforo-cortantes. Esas lesiones aumentan el riesgo biológico porque son la puerta de entrada para los virus y las bacterias. Algunos sistemas de abertura de ampollas (VIBRAC Y OPC), fueron desarrollados para reducir la incidencia de tales accidentes. Los materiales alternativos al vidrio pueden representar una estrategia interesante para aumentar la seguridad. El uso de jeringuillas esterilizadas y preparadas con anterioridad por el fabricante, podría ser una especie de evolución o avance con relación a la seguridad. CONCLUSIÓN: El entrenamiento del equipo y la aclaración por parte de la industria farmacéutica respecto del uso de las ampollas, es algo fundamental en la profilaxis de los accidentes y contaminaciones. Pero todavía es necesario descubrir nuevos sistemas de abertura de ampollas de forma más segura. No menos importante será la búsqueda de materiales seguros que sirvan de alternativa para el uso del vidrio.


Subject(s)
Drug Packaging , Drug Contamination/prevention & control , Drug Packaging/standards , Glass , Health Personnel , Occupational Injuries/prevention & control , Risk Factors , Risk Management
SELECTION OF CITATIONS
SEARCH DETAIL